{"id":13986,"date":"2011-01-31T13:52:18","date_gmt":"2011-01-31T20:52:18","guid":{"rendered":"https:\/\/serverlift.com\/?p=13986"},"modified":"2025-07-31T22:47:29","modified_gmt":"2025-07-31T22:47:29","slug":"conducting-server-moves-fully-loaded-rackscabinets","status":"publish","type":"post","link":"https:\/\/serverlift.com\/sv\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","title":{"rendered":"Ledande serverflyttningar med helt lastade rack \/ sk\u00e5p"},"content":{"rendered":"<p>Nyligen st\u00f6tte jag p\u00e5 en forumfr\u00e5ga som fr\u00e5gade efter ett bra s\u00e4tt att flytta ett helt befolkat serverst\u00e4ll eller sk\u00e5p. Kort sagt verkar det vara en bra id\u00e9 med tanke p\u00e5 vikten och sv\u00e5righeten att flytta stora, enskilda servrar. M\u00e5nga IT-personer ber\u00e4ttar f\u00f6r mig att deras tekniker utf\u00f6r en serverr\u00f6relse genom att ta ut de flesta komponenterna fr\u00e5n varje server innan de kan ta bort den fr\u00e5n racket, sedan flytta varje del och montera allt igen n\u00e4r sk\u00e5pet \u00e4r p\u00e5 plats.<\/p>\n<p>Sanningen \u00e4r att s\u00e5vida inte dina sk\u00e5p har byggts f\u00f6r r\u00f6rlighet (och ofta \u00e4ven om de \u00e4r) f\u00f6r att flytta ett helt befolkat, \u00e4r sk\u00e5p s\u00e4llan en bra id\u00e9.<\/p>\n<p>Gaffelhissar \u00e4r utformade f\u00f6r att flytta v\u00e4lpackade varor p\u00e5 en pall. Jag har sett datacenter vars sk\u00e5p \u00e4r p\u00e5 skridskor eller pallar, och om det \u00e4r s\u00e5 ditt \u00e4r utformat \u00e4r det tydligt att du redan har ett system f\u00f6r att flytta hela sk\u00e5p. Vanligtvis har dessa datacenter mycket stort g\u00e5ngutrymme eller finns i fr\u00f6skidor. F\u00f6r resten av oss, l\u00e4mna gaffeltrucken f\u00f6r lastningsbryggan. , Det har ingen plats att flytta dyr, \u00f6mt\u00e5lig IT-utrustning.<\/p>\n<p>L\u00e5t oss f\u00f6rst t\u00e4nka p\u00e5 att de flesta rack och sk\u00e5p inte har hjul och anv\u00e4nder sm\u00e5 ben f\u00f6r att st\u00f6dja dem. \u00c4ven om du \u00e4r tillr\u00e4ckligt stark f\u00f6r att st\u00f6dja ett sk\u00e5p n\u00e4r alla fyra benen \u00e4r p\u00e5 marken, n\u00e4r du lutar ett sk\u00e5p och l\u00e4gger sin vikt p\u00e5 tv\u00e5 ben, \u00f6kar du inte bara kraftigt belastningen men du vrider ocks\u00e5 de tunna benen i en vinkel de inte var utformad f\u00f6r att f\u00e5 dem att b\u00f6jas eller g\u00e5 s\u00f6nder. De flesta rack och sk\u00e5p \u00e4r helt enkelt inte flyttade n\u00e4r de \u00e4r bebodda.<\/p>\n<p>Vissa nyare racksystem \u00e4r utformade f\u00f6r att vara mobila med utrustning installerad, \u00e4ven om sv\u00e5righeter med tr\u00e5nga g\u00e5ngar kan leda till dig i en situation som \u00e4r sv\u00e5r att \u00f6vervinna, \u00e4ven till och med r\u00f6rliga sk\u00e5p kan vara problematiska i en snabb g\u00e5ngkonfiguration. De flesta \u00e4r sv\u00e5ra att flytta \u00f6ver upph\u00f6jda golv och tr\u00e5nga korsningar kan stoppa allt.<\/p>\n<p><strong>Det finns ett enklare s\u00e4tt att migrera tillg\u00e5ngar.<\/strong><\/p>\n<p><strong>De flesta drag faller inom tre omr\u00e5den:<\/strong><\/p>\n<p><strong> Migrering till ett nytt sk\u00e5p eller datacenter<\/strong><\/p>\n<p><strong> Konsolidering av tillg\u00e5ngar till ett mindre fotavtryck eller en ny anl\u00e4ggning<\/strong><\/p>\n<p><strong> Befolkning av ett nytt rack \/ sk\u00e5p f\u00f6r ny installation <\/strong><\/p>\n<ul>\n<li>Om du har anst\u00e4llt en effektivitetskonsult, se till att du informerar dem om din nya konfiguration innan du flyttar n\u00e5got. I de fall en effektivitetsmodell har skapats kan till och med den minsta f\u00f6r\u00e4ndringen f\u00f6r\u00e4ndra den fina balansen mellan utrymme, kylning och kraft.<\/li>\n<\/ul>\n<ul>\n<li>M\u00e4rk alla dina kablar och varje utrustning om du inte redan har gjort det. Trenden idag \u00e4r att anv\u00e4nda f\u00e4rgkodade kablar, men oavsett vilken metod du anv\u00e4nder, kartl\u00e4gg alltid din installation innan du tar bort n\u00e5got. Om du anv\u00e4nde Visio eller annan programvara f\u00f6r att utforma din konfiguration, se till att du inkluderar beroenden p\u00e5 det sk\u00e5pet f\u00f6r att f\u00f6rs\u00e4kra att du inte \u00e4r kritisk till en annan del av ditt system. H\u00e5ll det designdiagrammet i n\u00e4rheten f\u00f6r referens.<\/li>\n<li>Se till att du har speglat dina str\u00f6mkrav. t.ex. om du anv\u00e4nder 16A p\u00e5 ett sk\u00e5p, se till att sk\u00e5pet du flyttar till \u00e4r 16A.<\/li>\n<li>Katalogisera varje h\u00e5rdvara och den exakta platsen i sk\u00e5pet. Siffrorna p\u00e5 monteringsskenorna i racket hj\u00e4lper dig att identifiera dessa platser. F\u00e5 saker \u00e4r mer frustrerande \u00e4n att f\u00e5 ett sk\u00e5p n\u00e4stan fullt, bara f\u00f6r att inse att du har kort plats och att du m\u00e5ste b\u00f6rja om.<\/li>\n<li>M\u00e4rk dina monteringsskenor. \u00c4ven om r\u00e4lsen ofta ser ut s\u00e5 \u00e4r de kanske inte, och som vi vet \u00e4r de gjorda f\u00f6r varje utrustning. Var noga med att m\u00e4rka vilken utrustning som skenan motsvarar.<\/li>\n<li>Anv\u00e4nd en Data Center Infrastructure Handling (DCIH) -l\u00f6sning f\u00f6r att ta bort alla komponenter fr\u00e5n serverrack f\u00f6re en flytt och installera om n\u00e4r racket \u00e4r p\u00e5 plats. Se till att alla lyftanordningar som du anv\u00e4nder \u00e4r certifierade f\u00f6r datacenteranv\u00e4ndning.<\/li>\n<li>Detta \u00e4r en bra tid att omorganisera eventuella kablar eller str\u00f6mf\u00f6rs\u00f6rjning vid behov. Detta inneb\u00e4r ocks\u00e5 att det \u00e4r en bra tid att ta bort de oanv\u00e4nda kablarna som n\u00e5gon l\u00e4mnade kvar.<\/li>\n<li>Rackar med hjul ska flyttas tomma medan du trycker s\u00e5 l\u00e5gt ned p\u00e5 racket som m\u00f6jligt f\u00f6r att undvika tippning. Att ta bort d\u00f6rrarna och sidorna p\u00e5 ett sk\u00e5p kan g\u00f6ra det mindre stabilt men kan ocks\u00e5 minska vikten. Experimentera f\u00f6r att se vilka som passar b\u00e4st f\u00f6r dina behov.<\/li>\n<li>Reng\u00f6r sk\u00e5pet noggrant inifr\u00e5n och ut f\u00f6r att ta bort damm, och dubbelkontrollera f\u00f6r att se till att inga skenor \u00e4r b\u00f6jda och \u00e4r f\u00e4sta ordentligt. Det h\u00e4r \u00e4r en bra tid att byta ut glidskenor som har skadats.<\/li>\n<li>Oavsett om du fortfarande kablar under golvet eller anv\u00e4nder luftledningar, ta det extra steget och ta bort de gamla kablarna.<\/li>\n<li>Om du har ett iscenes\u00e4ttningsrum eller labb att arbeta i, flytta din h\u00e5rdvara dit f\u00f6rst och l\u00e5t din h\u00e5rdvarutekniker st\u00e4da upp allt medan du byter ut alla slitna komponenter som fl\u00e4ktar. Medan de g\u00f6r det, flyttar du sk\u00e5pet och driver din makt.<\/li>\n<\/ul>\n<p><strong>Anledningar till att inte flytta serverrack n\u00e4r den \u00e4r fulladdad:<\/strong><\/p>\n<ul>\n<li>Serverst\u00e4llet kan kollapsa, b\u00f6jas eller falla och skada personal eller skada utrustning.<\/li>\n<li>R\u00e4lsen kan bli b\u00f6jda, vilket g\u00f6r dem v\u00e4rdel\u00f6sa (b\u00f6jda r\u00e4ls \u00e4r sv\u00e5ra, om inte om\u00f6jliga, att reparera)<\/li>\n<li>De flesta serverrackar, hjul, bultar, monteringsh\u00e5rdvara osv \u00e4r inte betygsatta f\u00f6r r\u00f6relse, och \u00e4ven om det finns sk\u00e5p utformade f\u00f6r detta \u00e4r det tveksamt att du anv\u00e4nder dem, eftersom de \u00e4r mycket specialiserade.<\/li>\n<li>H\u00f6jda golv kanske inte har punktbelastningskapacitet n\u00e4r du minskar viktf\u00f6rdelningen fr\u00e5n m\u00e5nga r\u00f6rliga enheter, till exempel en handbil.<\/li>\n<li>H\u00f6jda golv och burtr\u00f6sklar beh\u00f6ver hjul som \u00e4r st\u00f6rre \u00e4n de flesta hjul f\u00f6r att s\u00e4kert rulla \u00f6ver dem.<\/li>\n<li>Och mest av allt, f\u00f6rst\u00e5 orsaken till att du vill flytta hela sk\u00e5pet och att du kanske \u00f6verv\u00e4ger om. \u00c4r det s\u00e5 att du inte kan lossa sk\u00e5pet eller \u00e4r det att du tror att det kan spara tid. Merparten av tiden vi har pratat med datacentretekniker \u00e4r det vanligtvis bara en tidsbesparing. T\u00e4nk p\u00e5 att en ServerLIFT \u00e4r den b\u00e4sta och mest konsekvent p\u00e5litliga tidsbespararen du har f\u00f6r detta.<\/li>\n<\/ul>\n<p>Some quotes to consider (from Dell servers \u2013 Moving a Server rack):<\/p>\n<p>MrTom (Programmer)<\/p>\n<p>\u201cTa definitivt bort allt! Jag tryckte en rack ner ett kabelh\u00e5l en g\u00e5ng och det var tillr\u00e4ckligt skr\u00e4mmande och det lutades bara n\u00e5gra grader \u00f6ver (jag f\u00f6rs\u00f6kte inte ens flytta det). L\u00e5ter som ett bra s\u00e4tt att sl\u00f6sa bort ett veckors arbete \u00e4nd\u00e5;) \u201d<\/p>\n<p>Kan han ha sparat lite tid och tunga lyft genom att anv\u00e4nda <a title=\"SL 500 ServerLIFT\" href=\"https:\/\/serverlift.com\/sv\/data-center-lifts\/sl-500x\/\">SL-500X ServerLIFT<\/a>?<\/p>","protected":false},"excerpt":{"rendered":"<p>Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":17159,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":"","_wpscppro_dont_share_socialmedia":null,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"","_instagram_share_type":"default","_medium_share_type":"","_threads_share_type":"","_google_business_share_type":"","_selected_social_profile":[],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[78],"tags":[],"class_list":["post-13986","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/serverlift.com\/sv\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae\" \/>\n<meta property=\"og:description\" content=\"Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/serverlift.com\/sv\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/\" \/>\n<meta property=\"og:site_name\" content=\"ServerLIFT\u00ae\" \/>\n<meta property=\"article:published_time\" content=\"2011-01-31T20:52:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-31T22:47:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1030\" \/>\n\t<meta property=\"og:image:height\" content=\"992\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"David Zuckerman\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"},\"author\":{\"name\":\"David Zuckerman\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\"},\"headline\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets\",\"datePublished\":\"2011-01-31T20:52:18+00:00\",\"dateModified\":\"2025-07-31T22:47:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"},\"wordCount\":1116,\"image\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"articleSection\":[\"Tech LIFT\"],\"inLanguage\":\"sv-SE\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\",\"url\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\",\"name\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets - ServerLIFT\u00ae\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"datePublished\":\"2011-01-31T20:52:18+00:00\",\"dateModified\":\"2025-07-31T22:47:29+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\",\"url\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"contentUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"width\":1030,\"height\":992,\"caption\":\"Rack Cabinet\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/serverlift.com\\\/sv\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#website\",\"url\":\"https:\\\/\\\/serverlift.com\\\/\",\"name\":\"ServerLIFT\u00ae\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/serverlift.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\",\"name\":\"David Zuckerman\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"url\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"contentUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"caption\":\"David Zuckerman\"},\"url\":\"https:\\\/\\\/serverlift.com\\\/sv\\\/author\\\/david-z\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/serverlift.com\/sv\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","og_locale":"sv_SE","og_type":"article","og_title":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","og_description":"Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]","og_url":"https:\/\/serverlift.com\/sv\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","og_site_name":"ServerLIFT\u00ae","article_published_time":"2011-01-31T20:52:18+00:00","article_modified_time":"2025-07-31T22:47:29+00:00","og_image":[{"width":1030,"height":992,"url":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","type":"image\/jpeg"}],"author":"David Zuckerman","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#article","isPartOf":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"},"author":{"name":"David Zuckerman","@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af"},"headline":"Conducting Server Moves with Fully Loaded Racks\/Cabinets","datePublished":"2011-01-31T20:52:18+00:00","dateModified":"2025-07-31T22:47:29+00:00","mainEntityOfPage":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"},"wordCount":1116,"image":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"thumbnailUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","articleSection":["Tech LIFT"],"inLanguage":"sv-SE"},{"@type":"WebPage","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","url":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","name":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","isPartOf":{"@id":"https:\/\/serverlift.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"image":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"thumbnailUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","datePublished":"2011-01-31T20:52:18+00:00","dateModified":"2025-07-31T22:47:29+00:00","author":{"@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af"},"breadcrumb":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage","url":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","contentUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","width":1030,"height":992,"caption":"Rack Cabinet"},{"@type":"BreadcrumbList","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/serverlift.com\/sv\/"},{"@type":"ListItem","position":2,"name":"Conducting Server Moves with Fully Loaded Racks\/Cabinets"}]},{"@type":"WebSite","@id":"https:\/\/serverlift.com\/#website","url":"https:\/\/serverlift.com\/","name":"ServerLIFT\u00ae","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/serverlift.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Person","@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af","name":"David Zuckerman","image":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","url":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","contentUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","caption":"David Zuckerman"},"url":"https:\/\/serverlift.com\/sv\/author\/david-z\/"}]}},"_links":{"self":[{"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/posts\/13986","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/comments?post=13986"}],"version-history":[{"count":4,"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/posts\/13986\/revisions"}],"predecessor-version":[{"id":37603,"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/posts\/13986\/revisions\/37603"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/media\/17159"}],"wp:attachment":[{"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/media?parent=13986"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/categories?post=13986"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/serverlift.com\/sv\/wp-json\/wp\/v2\/tags?post=13986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}