ServerLIFT vs. RackLift – Comparison of Functionality

This is the first installment of an ongoing series examining data center equipment. We will take a look at the stark differences between ServerLIFT® machines and other devices, and assess how they function as server handling tools. Our first comparison is of ServerLIFT® vs. RackLift. The comparison is categorized into the 3 essential functions of a server-handling device:
  1. Transportation
  2. Positioning
  3. Installation/Removal.

***It should be noted that “general-purpose” lifts —those not designed specifically for data center use—are not able to handle all three functions as described. Additionally, some lifts marketed as “purpose-built” do not effectively solve all 3 problems, exposing their users to unnecessary risks.

To counteract any false information provided elsewhere, a research team compared how ServerLIFT® and RackLift data center lifts perform in a series of tests. That study was conducted by the Product and Competitive Testing team at Arizona State University (with input from Industrial Design and Engineering teams).

Here were the key characteristics of a data center lift that were analyzed in the ASU study:

  • unit height and width
  • platform reach
  • floor clearance
  • mechanical safety
  • engineering
  • ergonomics

(This evaluation is model non-specific—it applies to all ServerLIFT® models and RackLift models equally, whether one relies on manual hand-cranking or an electric motor, for example.)

Function #1 – Transportation: ServerLIFT® vs. RackLift

Speed

A data center lift must move efficiently for server installation. From starting point to the target, the RackLift is slower and more cumbersome. A ServerLIFT® device moves through corridors 25% faster.

Navigation

A properly designed data center lift must maneuver down narrow aisles and turn smoothly around corners. The RackLift RL600 series requires a wider aisle (48 – 60” [121 – 152 cm]) for maneuvering and cannot turn smoothly around corners. The ServerLIFT® unit maneuvers comfortably in a narrower 36” (91 cm) aisle and can turn corners smoothly.

Access to Racks on Both Sides of the Aisle

Because most data centers have narrow aisles, the lift should be able to access server racks on both sides of the aisle without the need to rotate the device. With the RackLift device, servers can only be loaded in (or slid out) from the front, forcing operators to rotate the device to face and approach the rack. In order to work on both sides of a server, operators must therefore squeeze between the cabinets on the other side of the aisle and the lift. To then work at a rack on the other side of the aisle, the RackLift needs to be turned 180° the other way (which is not always possible, depending on aisle width).

The ServerLIFT® “Easy Glide” platform allows side-to-side installation, which gives the operator access to the rack on either side of the aisle. A ServerLIFT® device never needs to be turned around for the operator to switch and work on the other side of the aisle.

racklift aisle access
With RackLift, there’s only rack access on one side of the aisle.

serverlift rack access
With a ServerLIFT® device, you can access the rack via both sides of the aisle due to the gliding shelf.

Fitting Through Doors & Entryways

Data center lifts should be able to move equipment from one room to another through standard door frames and elevator entryways. RackLift units measure 82.75” (201 cm) tall, so they cannot fit through standard doors and elevator entryways that tend to measure anywhere from 78 to 82 inches (198-208 cm) high. To compensate, you’d need to tip the lift to move it through, risking serious injury.

ServerLIFT® units measure 69.5 inches (176.5 cm) high with its tower fully retracted (the SL-1000X model is 78 inches or 198 cm), so it’s able to pass through both standard door frames and elevator entrances with room to spare.

serverlift doorway access
ServerLIFT® devices fit through doorways.

racklift doorway
RackLift cannot fit through standard doorways.

Operator Observations

In the ASU study, both test operators found the RackLift difficult to navigate. As the report states, “Driving the RackLift was much harder for the two users. They had difficulty turning, stopping and braking the lift. The visibility was decreased significantly when the server was added and the handles were not very useful.”

As for the ServerLIFT® unit, maneuvering it “was generally easy for both users except for some minor details.”

Clearing Obstructions

A data center lift must be able to navigate over obstructions without damaging equipment or risking injury to the operator. The RackLift has a clearance of only half an inch (1.25 cm.) This low clearance prevents it from safely passing over power cord channels, ramps, and door thresholds, even when it is not loaded. This makes it likely to tip over, putting the onboard server, the operator, and surrounding equipment in serious danger.

The ServerLIFT® device, with nearly a full inch (2.5 cm) of ground clearance, safely passes over all types of obstructions, when loaded or unloaded, without tipping.

racklift clearance
RackLift clearance of only half an inch (1.25 cm.)

serverlift clearance
ServerLIFT® clearance of nearly a full inch (2.5 cm)

Function #2 – Positioning: ServerLIFT® vs. RackLift

Placing Servers into Racks

The ideal data center lift should help to install servers and other equipment into any rack and every rack unit. The RackLift device only reaches to the top of standard 42U racks.

On the other hand, with its extendable tower and modular platform accessories, the ServerLIFT® data center lift can safely support devices up to the top of a 62U rack (112 inches, or 284.5 cm).

racklift height
RackLift device only reaches to the top of standard 42U racks.

serverlift height
ServerLIFT® device reaches top of 62U racks.
Server handling lifts must also maintain a level platform. Post-to-post alignment and angled installations for slotted and drop-in rails is also required. RackLift’s extending shelf positions equipment in the rack, but cannot adjust the angle of the server. The operator must do so manually, both for side-to-side alignment and for drop-in rails. This is made even more difficult by the RackLift frame, which places a tech at high risk for pinched fingers or pulled muscles.

Only ServerLIFT® devices offer control over the alignment of servers. Any ServerLIFT® device can angle equipment into slotted and drop-in rails using the RS-500X Rail Lift.

racklift safety
RackLift’s extending shelf positions equipment in the rack but cannot adjust the angle of the server.

serverlift installations
Any ServerLIFT® device can angle equipment into slotted and drop-in rails.

Function #3 – Installation/Removal: ServerLIFT® vs. RackLift

The 3rd essential function of a data center lift is to assist with installing and removing servers in a safe and efficient manner. Both the ServerLIFT® and RackLift provide physical support for devices into and out of server cabinets.

However, the RackLift falls short in a number of associated categories, including operator access, stability, and support.

Access to Server During Install

There should be clear access to the server during installation into the rack. On the RackLift, this is not the case. The server is placed inside a four-post frame. This frame, along with stabilizing straps and the winch, obstructs or completely blocks visibility and access, forcing the operator to reach inside the frame to perform a dangerous server installation or removal.

ServerLIFT® devices provide completely clear and safe access to the server during the installation process. Rather than housing the server in a semi-enclosed frame, the ServerLIFT® platform supports the server forward and clear of its single vertical mast and lifting mechanisms, which are at the rear and out of the way. This leaves all sides of the server open, unobstructed, and available to the operator.

racklift access
The RackLift device obstructs or completely blocks visibility and access, forcing the operator to perform a dangerous server installation.

serverlift access
ServerLIFT® devices provide completely clear and safe access to the server during the installation process.

Lift Stabilization During Install

Data center lifts must be stabilized for safety at all times while equipment is being lifted, removed from or installed into racks. Because lifts are on rolling wheels, if they aren’t well-secured, the lift will move when equipment is sliding on or off of the platform, creating serious danger for the operator and the equipment.

To secure a RackLift, the operator must spend time strapping the device to the cabinet at four different points and applying the brake locks attached to the two rear wheels. The RackLift is dependent on the rack for support. The rack itself is often only secured to other racks in the aisle, and is filled with expensive servers. Without a rack, the RackLift and its equipment are in constant danger for rolling or tipping. This is why the RackLift is always shown being used with more than one person – one person is needed to stabilize it, and one to operate it.

racklift secure
Without a rack, the RackLift and its equipment are in constant danger for rolling or tipping. This is why the RackLift is always shown being used with more than one person.

serverlift stable
The ServerLIFT® device remains independently stable, and it will not move at all, with the brake on.

With a ServerLIFT® device, securing the lift requires the application of a single brake. The machine is locked down and rear wheels are lifted off of the floor. With this feature, the ServerLIFT® device remains independently stable, and it will not move at all when heavy servers are slid on or off it, providing constant, steady, reliable support. The brake pedal is large, easy to engage, and fully accessible at all times at the back of the unit.

Server Stabilization During Install

Both RackLift and ServerLIFT® devices provide horizontal shelf support into the rack, and RackLift even goes as far as providing an additional 14 inches of support. However, that extra shelf support length comes at the cost of extra device width, making it difficult to use in an aisle narrower than 60 inches (152 cm) and impossible to use in increasingly common 36-inch aisles.

ServerLIFT®’s built-in Easy Glide Shelf adds 6 inches of lateral movement to the left and right into the rack, allowing operators to walk around the unit and work comfortably even in aisles as narrow as 3 feet wide.

ServerLIFT® vs. RackLift: Weight Capacity

RackLift states that its RL600S hand-cranked lift has a greater weight capacity at 600 pounds (272 kg) than the 350 pounds (158.7 kg) capacity of the ServerLIFT® SL-350X hand-cranked device. This does not tell the whole story. First, lifting servers with a weight over 300 pounds (let alone 600 pounds) by hand cranking requires a tremendous amount of arm and shoulder strength. It is difficult work, and the amount of both effort and force risks injury to the operator.

That is why ServerLIFT® rates all of its server-handling solutions appropriately. We offer data center lift options in 500-pound (226 kg) and 1,000-pound (454 kg) capacities with electric winches, not the arm and shoulder of a data center technician. The ServerLIFT® SL-350X device that RackLift compares to its RL600S model was designed for a 350-pound weight limit because, as a manual hand-crank lift, it shouldn’t be used to lift greater weight. Manual hand cranking above the 350-pound limit poses inappropriate levels of physical strain, even for occasional use.

racklift crank
With RackLift, lifting servers with a weight over 300 pounds (let alone 600 pounds) by hand cranking requires a tremendous amount of arm and shoulder strength, risking injury to the operator.

serverlift operate
The ServerLIFT® SL-350X device was designed for a 350-pound weight limit because manual hand cranking above the 350-pound limit poses inappropriate levels of physical strain.

When choosing a data center lift, make sure that you choose a device that can handle 100% of the essential functions. Beware of misleading or even false claims by manufacturers that call their devices “purpose built.” A purpose-built device means that it was designed to handle all of the functional aspects of day-to-day data center operations. It cannot fall short in safely completing all tasks, forcing operators to risk an accident or injury.

To read more from ASU’s independent study, click here

Recommended Posts

Tech LIFT

The 7 Top Data Center Trends for 2024

Data centers play a crucial role in allowing enterprises to process, access, and store mission-critical data for their daily operations. As the world sees

Tech LIFT

6 Weird Data Center Locations

Many data centers are located in or near metropolitan areas because of their proximity to customers and to potential employees. However, as available land

enter the information below to download the whitepaper

The Data Center Migration Guide

enter the information below to download the whitepaper

The Data Center Safety Guidebook

enter the information below to download the whitepaper

Best Practices for Moving IT Department in the Data Center

enter the information below to download the whitepaper

Best Practices for Data Center Equipment Handling

enter the information below to download the whitepaper

data center consolidation action plan white paper

enter the information below to download the whitepaper

Buying a Data Center Lifting Device