{"id":4704,"date":"2018-08-22T12:15:08","date_gmt":"2018-08-22T19:15:08","guid":{"rendered":"https:\/\/serverlift.com\/?p=1220"},"modified":"2025-05-02T16:43:42","modified_gmt":"2025-05-02T16:43:42","slug":"tech-liftdata-center-relocationmigration-checklist","status":"publish","type":"post","link":"https:\/\/serverlift.com\/hu\/blog\/tech-liftdata-center-relocationmigration-checklist\/","title":{"rendered":"Adatk\u00f6zpont \u00e1thelyez\u00e9si \/ migr\u00e1ci\u00f3s ellen\u0151rz\u0151lista"},"content":{"rendered":"<p style=\"text-align: left;\"><a class=\"post-button\" href=\"https:\/\/serverlift.com\/wp-content\/uploads\/2024\/08\/DC-Migration-Checklist.xlsx\" target=\"_blank\" rel=\"noopener noreferrer\"><i class=\"fa fa-download\"><\/i> T\u00f6ltse le az adatk\u00f6zponti migr\u00e1ci\u00f3s ellen\u0151rz\u0151lista Excel-lapj\u00e1t<\/a><\/p>\n<p><i><span style=\"font-weight: 400;\"><strong>Friss\u00edtve 2019-re<\/strong>:<\/span><\/i><\/p>\n<p><a href=\"http:\/\/www.datacenterknowledge.com\/industry-perspectives\/modern-data-centers-battle-exponential-data-growth\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"font-weight: 400;\">Adatk\u00f6zpont-ismeretek<\/span><\/a><span style=\"font-weight: 400;\"> a k\u00f6zelm\u00faltban az exponenci\u00e1lis adatn\u00f6veked\u00e9st kritikus kih\u00edv\u00e1sk\u00e9nt hat\u00e1rozta meg az informatikai ipar sz\u00e1m\u00e1ra. Tov\u00e1bbi szervezetek mutatj\u00e1k be a migr\u00e1ci\u00f3 vagy az adatk\u00f6zpontok \u00e1thelyez\u00e9s\u00e9nek gondolat\u00e1t. Az egyik legfontosabb ok, amelyet a v\u00e1llalat az adatk\u00f6zpontok \u00e1thelyez\u00e9s\u00e9t tervezi, mag\u00e1ban foglalja a potenci\u00e1lis k\u00f6lts\u00e9gmegtakar\u00edt\u00e1st, a t\u00f6bb fizikai hely sz\u00fcks\u00e9gess\u00e9g\u00e9t \u00e9s a biztons\u00e1gi \/ megfelel\u00e9si k\u00e9rd\u00e9seket. Az okokt\u00f3l f\u00fcggetlen\u00fcl az adatk\u00f6zpontok \u00e1thelyez\u00e9se nagy kock\u00e1zattal j\u00e1r\u00f3 m\u0171velet \u00e9s megoldand\u00f3 feladat. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Az adatk\u00f6zpontok k\u00f6lt\u00f6z\u00e9se \u00e9s a migr\u00e1ci\u00f3 az \u00e9let elker\u00fclhetetlen t\u00e9ny\u00e9v\u00e9 v\u00e1lt. A modern adatk\u00f6zpontok \u00e1ltal\u00e1ban h\u00e1rom-\u00f6t alkalommal k\u00f6lt\u00f6znek, \u00e9s az 53% v\u00e1llalat arra sz\u00e1m\u00edt, hogy ezt megteszi a k\u00f6vetkez\u0151 \u00e9vekben - mondta Shawn Simon, a projekt vezet\u0151je <\/span><a href=\"https:\/\/nationalcws.com\/\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"font-weight: 400;\">National Computer Warehouse Services, LLC<\/span><\/a><span style=\"font-weight: 400;\"> (NCWS). <\/span><\/p>\n<p><span style=\"font-weight: 400;\">A leggyakoribb adatk\u00f6zponti k\u00f6lt\u00f6z\u00e9s Simon szerint k\u00e9tf\u00e9le munkav\u00e1llal\u00f3t \u00e9rint: <\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\"><b>H\u00e1zon bel\u00fcli szem\u00e9lyzet.<\/b><span style=\"font-weight: 400;\"><span style=\"font-weight: 400;\"> A h\u00e1zon bel\u00fcli alkalmazottak naponta mozgathatj\u00e1k a kiszolg\u00e1l\u00f3kat, de gyakran nem k\u00e9sz\u00fclnek fel az adatk\u00f6zponti migr\u00e1ci\u00f3 sor\u00e1n a hatalmas kiszolg\u00e1l\u00f3k \u00fczembe helyez\u00e9s\u00e9nek neh\u00e9z \u00e9s gyors jelleg\u00e9re. Fel kell k\u00e9sz\u00fclni\u00fck erre szakmai mozgat\u00f3kkal egyeztetve, \u00e9s tov\u00e1bbra is r\u00e9szt kell venni\u00fck a tervez\u00e9si folyamatban.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><b>Professzion\u00e1lis adatk\u00f6zpontok mozgat\u00f3i.<\/b><span style=\"font-weight: 400;\"> A hivat\u00e1sos mozgat\u00f3 gondoskodik a fizikai mozgat\u00e1sr\u00f3l, ide\u00e9rtve a kisz\u00e1ll\u00edtott \u00e9s elk\u00e9sz\u00edtett kiszolg\u00e1l\u00f3kat, valamint az \u00f6sszes olyan nagy darabot, mint a szekr\u00e9nyek \u00e9s a b\u00fatorok. Gy\u0151z\u0151dj\u00f6n meg r\u00f3la, hogy kapcsolatba l\u00e9p egy tapasztalt partnerrel, aki sz\u00e9les k\u00f6r\u0171 ismeretekkel rendelkezik a bek\u00f6lt\u00f6z\u00e9s sor\u00e1n felmer\u00fclt bonyolults\u00e1gokr\u00f3l. Ezzel k\u00fcl\u00f6nbs\u00e9get tehet a z\u00f6kken\u0151mentes \u00e1tmenet \u00e9s a lehets\u00e9ges r\u00e9m\u00e1lom k\u00f6z\u00f6tt.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">A h\u00e1zon bel\u00fcli szem\u00e9lyzet bevon\u00e1sa, bele\u00e9rtve az ir\u00e1ny\u00edt\u00e1st, a k\u00f6lts\u00e9gvet\u00e9s-tervez\u00e9st \u00e9s a l\u00e9tes\u00edtm\u00e9nyek karbantart\u00e1s\u00e1t, seg\u00edthet elker\u00fclni az informatikai szem\u00e9lyzet k\u00fcls\u0151 meglepet\u00e9seit, \u00e9s megk\u00f6nny\u00edti a v\u00e1llalati bev\u00e1s\u00e1rl\u00e1st. A folyamat elej\u00e9n hozza l\u00e9tre \u00e9s gyakorolja az er\u0151fesz\u00edt\u00e9sek \u00f6sszehangol\u00e1s\u00e1t a h\u00e1zon bel\u00fcli szem\u00e9lyzet \u00e9s a szakmai szerepl\u0151k k\u00f6z\u00f6tt. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">B\u00e1r az \u00f6sszes adatk\u00f6zponti migr\u00e1ci\u00f3s projekt a v\u00e1llalat ig\u00e9nyei alapj\u00e1n bizonyos egyedi d\u00f6nt\u00e9seket ig\u00e9nyel, vannak olyan szabv\u00e1nyos bev\u00e1lt gyakorlatok, amelyek megk\u00f6nny\u00edtik az \u00e1thelyez\u00e9st. Itt tal\u00e1lhat\u00f3 egy gyors migr\u00e1ci\u00f3s ellen\u0151rz\u0151 lista a fontos szempontokr\u00f3l, amelyeket figyelembe kell venni a k\u00f6lt\u00f6ztet\u00e9s el\u0151tt:<\/span><\/p>\n<h2>Adatk\u00f6zpont \u00e1thelyez\u00e9si \/ migr\u00e1ci\u00f3s ellen\u0151rz\u0151lista<\/h2>\n<h3>1) Projekttervez\u00e9s<\/h3>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Nagy k\u00f6lt\u00f6z\u00e9sekhez v\u00e1lasszon egy tapasztalt, tan\u00fas\u00edtott k\u00f6lt\u00f6ztet\u00e9si v\u00e1llalkoz\u00e1st, aki tapasztalattal rendelkezik adatk\u00f6zponttal.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Hozza l\u00e9tre \u00e9s gyakorolja a koordin\u00e1ci\u00f3t az adatk\u00f6zpontok mozgat\u00f3i \u00e9s a h\u00e1zon bel\u00fcli szem\u00e9lyzet k\u00f6z\u00f6tt. <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">K\u00f6lts\u00e9gvet\u00e9s \u00e9s adatk\u00f6zpont-\u00e1thelyez\u00e9si terv kidolgoz\u00e1sa, bele\u00e9rtve:<\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Id\u0151 \u00e9s er\u0151fesz\u00edt\u00e9s tervez\u00e9se<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">\u00daj l\u00e9tes\u00edtm\u00e9ny beszerz\u00e9si, \u00e9rt\u00e9kel\u00e9si \u00e9s fel\u00faj\u00edt\u00e1si k\u00f6lts\u00e9gei <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Tov\u00e1bbi szem\u00e9lyzet<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">T\u00fal\u00f3ra<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">\u00c1thelyez\u0151 c\u00e9g k\u00f6lts\u00e9ge<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">A kock\u00e1zat azonos\u00edt\u00e1sa<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">K\u00e9szenl\u00e9ti terv<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Lehets\u00e9ges szervercsere vagy diverzifik\u00e1ci\u00f3<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">H\u0171t\u00e9si k\u00f6vetelm\u00e9nyek<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Infrastrukt\u00fara megszerz\u00e9se \u00e9s m\u00f3dos\u00edt\u00e1sa<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Bek\u00f6t\u00e9se \/ k\u00e1belez\u00e9s<\/span><\/li>\n<\/ul>\n<\/li>\n<li>\u00dctemezze az \u00f6sszes telep\u00edt\u00e9si \u00e9s \u00fajratelep\u00edt\u00e9si esem\u00e9nyt<\/li>\n<li><span style=\"font-weight: 400;\">Ellen\u0151rizze az \u00f6sszes hardver \u00e9s virtu\u00e1lis rendszer elem\u00e9nek k\u00e9szlet\u00e9t, megjegyezve: <\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Berendez\u00e9s \u00e1llapota<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">M\u00e9ret<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">S\u00faly<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Sorozatsz\u00e1mok<\/span><\/li>\n<\/ul>\n<\/li>\n<li>Tekintse \u00e1t \u00e9s friss\u00edtse a teljes rendszerdiagramot<\/li>\n<\/ul>\n<h3>2) Telep\u00edt\u00e9s el\u0151tti dokument\u00e1ci\u00f3, garancia \u00e9s biztos\u00edt\u00e1si fedezet<\/h3>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">N\u00e9zze \u00e1t a gy\u00e1rt\u00f3 szavatoss\u00e1g\u00e1t<\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Jelenlegi lefedetts\u00e9g <\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">A kiszolg\u00e1l\u00f3k telep\u00edt\u00e9s\u00e9t vagy elt\u00e1vol\u00edt\u00e1s\u00e1t \u00e9rint\u0151 lehets\u00e9ges korl\u00e1toz\u00e1sok<\/span><\/li>\n<\/ul>\n<\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Ellen\u0151rizze \u00e9s vizsg\u00e1lja fel\u00fcl a bels\u0151 biztos\u00edt\u00e1si k\u00f6tv\u00e9nyeket<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Ellen\u0151rizze \u00e9s \u00e9rtse meg a mozgat\u00f3 biztos\u00edt\u00e1si fedezet\u00e9nek felt\u00e9teleit<\/span><\/li>\n<\/ul>\n<h3>3) Szerver el\u0151tti telep\u00edt\u00e9s<\/h3>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">K\u00e9sz\u00edtse el\u0151 a c\u00e9lkiszolg\u00e1l\u00f3-ter\u00fcletet<\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">H\u00e1l\u00f3zati kapcsolat<\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Biztos\u00edtsa az internet-kapcsolatot<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Elrendez\u00e9s \/ szerver szoba diagram<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">H\u00e1l\u00f3zati k\u00e1belez\u00e9s<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Energiagazd\u00e1lkod\u00e1s<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Rack elhelyez\u00e9s<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">VPN<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">DNS<\/span><\/li>\n<\/ul>\n<\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">K\u00e9sz\u00edtsen el\u0151 h\u00e1zon bel\u00fcli telep\u00edt\u00e9si r\u00e9sztvev\u0151ket<\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Biztons\u00e1gi elj\u00e1r\u00e1s oktat\u00e1sa<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">A szerver \u00fczembe helyez\u00e9si protokoll\u00e1nak edz\u00e9se \/ pr\u00f3ba, amely a k\u00f6vetkez\u0151ket tartalmazza:<\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">C\u00edmk\u00e9z\u0151 \u00e9s csomagol\u00f3 berendez\u00e9sek<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">K\u00e1belek<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">s\u00ednek<\/span><\/li>\n<\/ul>\n<\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">P\u00e1ros\u00edtson tapasztalt partnereket els\u0151 alkalommal<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Eml\u00e9keztesse az alkalmazottakat az adatk\u00f6zpont emel\u00e9s\u00e9nek el\u00e9rhet\u0151s\u00e9g\u00e9re \u00e9s fontoss\u00e1g\u00e1ra a szerver sz\u00e1m\u00e1ra:<\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Telep\u00edt\u00e9s \/ k\u00f6lt\u00f6ztet\u00e9s<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Sz\u00e1ll\u00edt\u00e1s<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Positioning<\/span><\/li>\n<\/ul>\n<\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">\u00c9les\u00edtse a vezet\u0151ket a program \u00fctemez\u00e9s\u00e9vel \u00e9s a kiszolg\u00e1l\u00f3 szoba diagramokkal<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Tan\u00e1csolja az alkalmazottakat \u00e9s az \u00fcgyfeleket a k\u00f6zelg\u0151 rendszerle\u00e1ll\u00e1sr\u00f3l<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">\u00dctemezze a projekt menedzser\u00e9t a helysz\u00ednen t\u00f6rt\u00e9n\u0151 munkav\u00e9gz\u00e9sre a kezdetekt\u0151l a kijelentkez\u00e9sig<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>4) H\u00e1zon bel\u00fcli hardver \u00e9s szoftver el\u0151k\u00e9sz\u00edt\u00e9se<\/h3>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Tekintse \u00e1t \u00e9s friss\u00edtse az egyes \u00e1llv\u00e1nyok diagramjait \u00e9s list\u00e1it<\/span>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Ellen\u0151rizze a kabinet fizikai el\u00e9rhet\u0151s\u00e9g\u00e9t<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Ellen\u0151rizze a biztons\u00e1gosan t\u00e1rolt biztons\u00e1gi m\u00e1solatot<\/span><\/li>\n<\/ul>\n<\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Ellen\u0151rizze a 100% virtu\u00e1lis eszk\u00f6z\u00f6k biztons\u00e1gi m\u00e1solat\u00e1t<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Azonos\u00edtsa \u00e9s \u00fctemezze az \u00e1tt\u00e9r\u00e9s sor\u00e1n v\u00e9grehajtand\u00f3 friss\u00edt\u00e9seket<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">K\u00e9sz\u00edtse el az \u00f6sszes hardvert \u00e9s virtu\u00e1lis rendszerelemet<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Azonos\u00edtsa \u00e9s t\u00e1vol\u00edtsa el a felesleges elhagyott k\u00e1beleket<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Charge and inspect ServerLIFT<sup>\u00ae<\/sup> device<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Ellen\u0151rizze a targonca rendelkez\u00e9sre \u00e1ll\u00e1s\u00e1t<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Ellen\u0151rizze az \u00fct\u00e9s-, nedvess\u00e9g- \u00e9s egy\u00e9b vesz\u00e9ly\u00e1ll\u00f3 csomagol\u00f3anyagok rendelkez\u00e9sre \u00e1ll\u00e1s\u00e1t<\/span><\/li>\n<\/ul>\n<h3>5) A szerver telep\u00edt\u00e9s\u00e9nek v\u00e9grehajt\u00e1sa<\/h3>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">T\u00fck\u00f6rteljes\u00edtm\u00e9ny-k\u00f6vetelm\u00e9nyek a szekr\u00e9nyek cser\u00e9jekor<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Kapcsolja ki a kiszolg\u00e1l\u00f3kat, a t\u00e1rol\u00f3 \u00e9s a h\u00e1l\u00f3zati eszk\u00f6z\u00f6ket a l\u00e9trehozott protokollnak megfelel\u0151en<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Az \u00e1llv\u00e1nyok \u00fajrat\u00f6lt\u00e9se el\u0151tt ellen\u0151rizze, tiszt\u00edtsa meg, jav\u00edtsa ki \u00e9s t\u00e1rolja \u00fajra az \u00e1rucikkeket<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Projektmenedzser jelentkezik a hardverlist\u00e1n \u00e9s az \u00fctemezett teszteken, miut\u00e1n az \u00f6sszes elem telep\u00edt\u00e9sre ker\u00fclt \u00e9s lelt\u00e1rba ker\u00fclt<\/span><\/li>\n<\/ul>\n<h3>K\u00f6vetkeztet\u00e9s<\/h3>\n<p><span style=\"font-weight: 400;\">Szerencs\u00e9re, b\u00e1r a t\u00e9nyleges l\u00e9p\u00e9s gyors \u00e9s d\u00fch\u00f6s, ugyanakkor r\u00f6vid \u00e9let\u0171. Az er\u0151fesz\u00edt\u00e9sek nagy r\u00e9sze a hat\u00e9kony tervez\u00e9sen rejlik. Seg\u00edtsen \u00f6nnek \u00e9s munkat\u00e1rsainak, hogy elker\u00fclj\u00e9k a lehet\u0151 legt\u00f6bb stresszt, ha id\u0151t \u00e9s er\u0151fesz\u00edt\u00e9st fektetnek az egy\u00fcttm\u0171k\u00f6d\u00e9sen alapul\u00f3 tervez\u00e9sre. Ne feledje, hogy az \u00fcgyes koordin\u00e1ci\u00f3 \u00e9s az eszk\u00f6z\u00f6k k\u00f6z\u00f6tti egy\u00fcttm\u0171k\u00f6d\u00e9s minimaliz\u00e1lja a felmer\u00fcl\u0151 esetleges neh\u00e9zs\u00e9geket. A projekthez szakosodott tan\u00e1csad\u00f3 vagy migr\u00e1ci\u00f3s koordin\u00e1tor bevon\u00e1sa seg\u00edthet csapatainak elker\u00fclni a gyakori buktat\u00f3kat. A kifizet\u00e9s meg\u00e9ri.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Term\u00e9szetesen a biztons\u00e1got az eg\u00e9sz folyamatban el\u0151t\u00e9rben fogja tartani. A biztons\u00e1gos l\u00e9p\u00e9s z\u00f6kken\u0151mentes l\u00e9p\u00e9s, amely viszont cs\u00f6kkenti az \u00e1ll\u00e1sid\u0151, a s\u00e9r\u00fcl\u00e9s vagy a berendez\u00e9s s\u00e9r\u00fcl\u00e9s\u00e9nek kock\u00e1zat\u00e1t. \u00c9s kezdje kor\u00e1n - \u00e9rdemes id\u0151t ford\u00edtani a helyes v\u00e9grehajt\u00e1s\u00e1ra.<\/span><\/p>\n<p style=\"text-align: left;\"><a class=\"post-button\" href=\"https:\/\/serverlift.com\/wp-content\/uploads\/2024\/08\/DC-Migration-Checklist.xlsx\" target=\"_blank\" rel=\"noopener noreferrer\"><i class=\"fa fa-download\"><\/i> T\u00f6ltse le az adatk\u00f6zponti migr\u00e1ci\u00f3s ellen\u0151rz\u0151lista Excel-lapj\u00e1t<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Moving a data center from one location to another is unarguably a high risk and arduous task to tackle. Here is a quick checklists of important aspects that should be considered before the move.<\/p>","protected":false},"author":34,"featured_media":17274,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":"","_wpscppro_dont_share_socialmedia":null,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"","_instagram_share_type":"default","_medium_share_type":"","_threads_share_type":"","_google_business_share_type":"","_selected_social_profile":[],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[78],"tags":[],"class_list":["post-4704","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Data Center Relocation | Migration Checklist | ServerLIFT\u00ae<\/title>\n<meta name=\"description\" content=\"Planning a data center relocation? Here is a quick data center migration checklist of important aspects that should be considered before the move.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/serverlift.com\/hu\/blog\/tech-liftdata-center-relocationmigration-checklist\/\" \/>\n<meta property=\"og:locale\" content=\"hu_HU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Data Center Relocation | Migration Checklist | ServerLIFT\u00ae\" \/>\n<meta property=\"og:description\" content=\"Planning a data center relocation? Here is a quick data center migration checklist of important aspects that should be considered before the move.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/serverlift.com\/hu\/blog\/tech-liftdata-center-relocationmigration-checklist\/\" \/>\n<meta property=\"og:site_name\" content=\"ServerLIFT\u00ae\" \/>\n<meta property=\"article:published_time\" content=\"2018-08-22T19:15:08+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-02T16:43:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/serverlift.com\/wp-content\/uploads\/2018\/08\/helloquence-61189-unsplash-1024x683.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"John Spillane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/\"},\"author\":{\"name\":\"John Spillane\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/99881ba28497f665a4fc87dec7660194\"},\"headline\":\"Data Center Relocation \\\/ Migration Checklist\",\"datePublished\":\"2018-08-22T19:15:08+00:00\",\"dateModified\":\"2025-05-02T16:43:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/\"},\"wordCount\":837,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2018\\\/08\\\/helloquence-61189-unsplash.jpg\",\"articleSection\":[\"Tech LIFT\"],\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/\",\"url\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/\",\"name\":\"Data Center Relocation | Migration Checklist | ServerLIFT\u00ae\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2018\\\/08\\\/helloquence-61189-unsplash.jpg\",\"datePublished\":\"2018-08-22T19:15:08+00:00\",\"dateModified\":\"2025-05-02T16:43:42+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/99881ba28497f665a4fc87dec7660194\"},\"description\":\"Planning a data center relocation? Here is a quick data center migration checklist of important aspects that should be considered before the move.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/#breadcrumb\"},\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/#primaryimage\",\"url\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2018\\\/08\\\/helloquence-61189-unsplash.jpg\",\"contentUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2018\\\/08\\\/helloquence-61189-unsplash.jpg\",\"width\":7360,\"height\":4912,\"caption\":\"data center migration or relocation checklist\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/tech-liftdata-center-relocationmigration-checklist\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/serverlift.com\\\/hu\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Data Center Relocation \\\/ Migration Checklist\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#website\",\"url\":\"https:\\\/\\\/serverlift.com\\\/\",\"name\":\"ServerLIFT\u00ae\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/serverlift.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"hu\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/99881ba28497f665a4fc87dec7660194\",\"name\":\"John Spillane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/image-1-96x96.png\",\"url\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/image-1-96x96.png\",\"contentUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/image-1-96x96.png\",\"caption\":\"John Spillane\"},\"url\":\"https:\\\/\\\/serverlift.com\\\/hu\\\/author\\\/jspillane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Data Center Relocation | Migration Checklist | ServerLIFT\u00ae","description":"Adatk\u00f6zpontok \u00e1thelyez\u00e9s\u00e9t tervezi? Itt tal\u00e1lhat\u00f3 egy gyors adatk\u00f6zpont-migr\u00e1ci\u00f3s ellen\u0151rz\u0151 lista a fontos szempontokr\u00f3l, amelyeket figyelembe kell venni a k\u00f6lt\u00f6ztet\u00e9s el\u0151tt.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/serverlift.com\/hu\/blog\/tech-liftdata-center-relocationmigration-checklist\/","og_locale":"hu_HU","og_type":"article","og_title":"Data Center Relocation | Migration Checklist | ServerLIFT\u00ae","og_description":"Planning a data center relocation? Here is a quick data center migration checklist of important aspects that should be considered before the move.","og_url":"https:\/\/serverlift.com\/hu\/blog\/tech-liftdata-center-relocationmigration-checklist\/","og_site_name":"ServerLIFT\u00ae","article_published_time":"2018-08-22T19:15:08+00:00","article_modified_time":"2025-05-02T16:43:42+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/serverlift.com\/wp-content\/uploads\/2018\/08\/helloquence-61189-unsplash-1024x683.jpg","type":"image\/jpeg"}],"author":"John Spillane","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/#article","isPartOf":{"@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/"},"author":{"name":"John Spillane","@id":"https:\/\/serverlift.com\/#\/schema\/person\/99881ba28497f665a4fc87dec7660194"},"headline":"Data Center Relocation \/ Migration Checklist","datePublished":"2018-08-22T19:15:08+00:00","dateModified":"2025-05-02T16:43:42+00:00","mainEntityOfPage":{"@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/"},"wordCount":837,"commentCount":0,"image":{"@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/#primaryimage"},"thumbnailUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2018\/08\/helloquence-61189-unsplash.jpg","articleSection":["Tech LIFT"],"inLanguage":"hu","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/","url":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/","name":"Data Center Relocation | Migration Checklist | ServerLIFT\u00ae","isPartOf":{"@id":"https:\/\/serverlift.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/#primaryimage"},"image":{"@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/#primaryimage"},"thumbnailUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2018\/08\/helloquence-61189-unsplash.jpg","datePublished":"2018-08-22T19:15:08+00:00","dateModified":"2025-05-02T16:43:42+00:00","author":{"@id":"https:\/\/serverlift.com\/#\/schema\/person\/99881ba28497f665a4fc87dec7660194"},"description":"Adatk\u00f6zpontok \u00e1thelyez\u00e9s\u00e9t tervezi? Itt tal\u00e1lhat\u00f3 egy gyors adatk\u00f6zpont-migr\u00e1ci\u00f3s ellen\u0151rz\u0151 lista a fontos szempontokr\u00f3l, amelyeket figyelembe kell venni a k\u00f6lt\u00f6ztet\u00e9s el\u0151tt.","breadcrumb":{"@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/#breadcrumb"},"inLanguage":"hu","potentialAction":[{"@type":"ReadAction","target":["https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/"]}]},{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/#primaryimage","url":"https:\/\/serverlift.com\/wp-content\/uploads\/2018\/08\/helloquence-61189-unsplash.jpg","contentUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2018\/08\/helloquence-61189-unsplash.jpg","width":7360,"height":4912,"caption":"data center migration or relocation checklist"},{"@type":"BreadcrumbList","@id":"https:\/\/serverlift.com\/blog\/tech-liftdata-center-relocationmigration-checklist\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/serverlift.com\/hu\/"},{"@type":"ListItem","position":2,"name":"Data Center Relocation \/ Migration Checklist"}]},{"@type":"WebSite","@id":"https:\/\/serverlift.com\/#website","url":"https:\/\/serverlift.com\/","name":"ServerLIFT\u00ae","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/serverlift.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hu"},{"@type":"Person","@id":"https:\/\/serverlift.com\/#\/schema\/person\/99881ba28497f665a4fc87dec7660194","name":"John Spillane","image":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/serverlift.com\/wp-content\/uploads\/2025\/09\/image-1-96x96.png","url":"https:\/\/serverlift.com\/wp-content\/uploads\/2025\/09\/image-1-96x96.png","contentUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2025\/09\/image-1-96x96.png","caption":"John Spillane"},"url":"https:\/\/serverlift.com\/hu\/author\/jspillane\/"}]}},"_links":{"self":[{"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/posts\/4704","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/comments?post=4704"}],"version-history":[{"count":12,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/posts\/4704\/revisions"}],"predecessor-version":[{"id":29546,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/posts\/4704\/revisions\/29546"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/media\/17274"}],"wp:attachment":[{"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/media?parent=4704"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/categories?post=4704"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/tags?post=4704"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}