{"id":13986,"date":"2011-01-31T13:52:18","date_gmt":"2011-01-31T20:52:18","guid":{"rendered":"https:\/\/serverlift.com\/?p=13986"},"modified":"2025-07-31T22:47:29","modified_gmt":"2025-07-31T22:47:29","slug":"conducting-server-moves-fully-loaded-rackscabinets","status":"publish","type":"post","link":"https:\/\/serverlift.com\/hu\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","title":{"rendered":"Szervermozgat\u00e1sok v\u00e9grehajt\u00e1sa teljesen bet\u00f6lt\u00f6tt \u00e1llv\u00e1nyokkal \/ szekr\u00e9nyekkel"},"content":{"rendered":"<p>Nemr\u00e9g tal\u00e1lkoztam egy f\u00f3rum k\u00e9rd\u00e9s\u00e9vel, amelyben felmer\u00fcl a j\u00f3 k\u00e9rd\u00e9s, hogy mik\u00e9nt lehet \u00e1thelyezni egy teljesen lakott szerver\u00e1llv\u00e1nyt vagy kabinet. R\u00f6viden, nagyszer\u0171 \u00f6tletnek t\u0171nik, tekintettel a nagy, egyedi kiszolg\u00e1l\u00f3k mozgat\u00e1s\u00e1nak s\u00faly\u00e1ra \u00e9s neh\u00e9zs\u00e9geire. Sok IT-ember azt mondja nekem, hogy technikusaik szervermozgat\u00e1st hajtanak v\u00e9gre \u00fagy, hogy az egyes kiszolg\u00e1l\u00f3kt\u00f3l elt\u00e1vol\u00edtj\u00e1k az alkatr\u00e9szek nagy r\u00e9sz\u00e9t, miel\u0151tt elt\u00e1vol\u00edthatj\u00e1k azokat a rackb\u0151l, majd mozgatj\u00e1k az egyes alkatr\u00e9szeket \u00e9s \u00f6sszeszerelik mindent, miut\u00e1n a szekr\u00e9ny a hely\u00e9n van.<\/p>\n<p>Az igazs\u00e1g az, hogy ha a szekr\u00e9nyeit nem a mobilit\u00e1s \u00e9rdek\u00e9ben \u00e9p\u00edtett\u00e9k fel (\u00e9s gyakran m\u00e9g akkor is, ha \u00e9ppen), hogy teljesen lakott mozgat\u00e1st v\u00e9gezzenek, a szekr\u00e9ny ritk\u00e1n j\u00f3 \u00f6tlet.<\/p>\n<p>A vill\u00e1s emel\u0151ket \u00fagy tervezt\u00e9k, hogy j\u00f3l csomagolt \u00e1rukat raklapon sz\u00e1ll\u00edtsanak. L\u00e1ttam olyan adatk\u00f6zpontokat, amelyek szekr\u00e9nyei cs\u00fasztatva vagy raklapon helyezkednek el, \u00e9s ha ez a saj\u00e1t tervez\u00e9sed szerint van, egy\u00e9rtelm\u0171, hogy m\u00e1r van rendszere a teljes szekr\u00e9nyek mozgat\u00e1s\u00e1hoz. Ezeknek az adatk\u00f6zpontoknak \u00e1ltal\u00e1ban nagyon nagy a folyos\u00f3ter\u00fclet\u00fck, vagy Pods-ban vannak. A t\u00f6bbiek sz\u00e1m\u00e1ra hagyjuk a targonc\u00e1t a rakod\u00f3\u00e1llom\u00e1s sz\u00e1m\u00e1ra. , Nincs helye dr\u00e1ga, t\u00f6r\u00e9keny IT-berendez\u00e9sek mozgat\u00e1s\u00e1ra.<\/p>\n<p>El\u0151sz\u00f6r n\u00e9zz\u00fck meg, hogy a legt\u00f6bb \u00e1llv\u00e1nyon \u00e9s szekr\u00e9nyben nincs g\u00f6rg\u0151, \u00e9s apr\u00f3 l\u00e1bakkal t\u00e1masztj\u00e1k al\u00e1 \u0151ket. Annak ellen\u00e9re, hogy el\u00e9g er\u0151s ahhoz, hogy t\u00e1mogassa a szekr\u00e9nyt, amikor mind a n\u00e9gy l\u00e1b a f\u00f6ld\u00f6n van, amikor a szekr\u00e9nyt megd\u00f6nti, \u00e9s annak s\u00faly\u00e1t k\u00e9t l\u00e1bra helyezi, akkor nemcsak jelent\u0151sen megn\u00f6veli a pontterhel\u00e9st, hanem megh\u00fazza azokat a v\u00e9kony l\u00e1bakat is olyan sz\u00f6gben, amelyben nem voltak. Aj\u00e1nlott: hajl\u00edt\u00e1shoz vagy t\u00f6r\u00e9shez. A legt\u00f6bb \u00e1llv\u00e1nyt \u00e9s szekr\u00e9nyt egyszer\u0171en nem \u00fagy helyezik el, hogy lak\u00f3hely\u00fck\u00f6n mozgathass\u00e1k.<\/p>\n<p>Egyes \u00fajabb \u00e1llv\u00e1nyrendszereket \u00fagy tervezt\u00e9k, hogy mozgathat\u00f3ak legyenek felszerelve a felszerel\u00e9ssel, b\u00e1r a zs\u00fafolt folyos\u00f3k neh\u00e9zs\u00e9gei neh\u00e9z helyzetbe hozhatj\u00e1k \u00d6nt, \u00e1m a sz\u0171k folyos\u00f3konfigur\u00e1ci\u00f3ban m\u00e9g mozgathat\u00f3 szekr\u00e9nyek is probl\u00e9m\u00e1k lehetnek. A legt\u00f6bb nehezen mozgathat\u00f3 emelt padl\u00f3n, \u00e9s a sz\u0171k keresztez\u0151d\u00e9sek mindent meg\u00e1ll\u00edthatnak.<\/p>\n<p><strong>Az eszk\u00f6z\u00f6k k\u00f6lt\u00f6ztet\u00e9se egyszer\u0171bb.<\/strong><\/p>\n<p><strong>A legt\u00f6bb l\u00e9p\u00e9s h\u00e1rom ter\u00fcletre esik:<\/strong><\/p>\n<p><strong> \u00c1tt\u00e9r\u00e9s egy \u00faj szekr\u00e9nybe vagy adatk\u00f6zpontba<\/strong><\/p>\n<p><strong> Eszk\u00f6z\u00f6k konszolid\u00e1l\u00e1sa kisebb l\u00e1bnyomra vagy \u00faj l\u00e9tes\u00edtm\u00e9nyre<\/strong><\/p>\n<p><strong> \u00daj rack \/ szekr\u00e9ny felt\u00f6lt\u00e9se az \u00faj telep\u00edt\u00e9shez <\/strong><\/p>\n<ul>\n<li>Ha hat\u00e9konys\u00e1gi tan\u00e1csad\u00f3t b\u00e9relt fel, akkor miel\u0151tt b\u00e1rmit \u00e1thelyezne, felt\u00e9tlen\u00fcl t\u00e1j\u00e9koztassa \u0151ket az \u00faj konfigur\u00e1ci\u00f3r\u00f3l. Azokban az esetekben, amikor hat\u00e9konys\u00e1gi modellt hoztak l\u00e9tre, m\u00e9g a legkisebb v\u00e1ltoztat\u00e1s is megv\u00e1ltoztathatja a helyis\u00e9g, a h\u0171t\u00e9s \u00e9s az energia finom egyens\u00faly\u00e1t.<\/li>\n<\/ul>\n<ul>\n<li>C\u00edmk\u00e9zze meg minden k\u00e1bel\u00e9t \u00e9s minden berendez\u00e9st, ha m\u00e9g nem tette meg. Manaps\u00e1g a tendencia a sz\u00ednk\u00f3d\u00fa k\u00e1belek haszn\u00e1lata, de f\u00fcggetlen\u00fcl att\u00f3l, hogy milyen m\u00f3dszert haszn\u00e1l, mindig rajzolja meg a be\u00e1ll\u00edt\u00e1st, miel\u0151tt b\u00e1rmit elt\u00e1vol\u00edtana. Ha Visio-t vagy m\u00e1s szoftvert haszn\u00e1lt a konfigur\u00e1ci\u00f3 megtervez\u00e9s\u00e9hez, \u00fcgyeljen arra, hogy az adott szekr\u00e9ny minden f\u00fcgg\u0151s\u00e9g\u00e9t felvegye annak biztos\u00edt\u00e1sa \u00e9rdek\u00e9ben, hogy nem kritikus a rendszer egy m\u00e1sik r\u00e9sz\u00e9re. Tartsa mindig a tervez\u00e9si diagramot a k\u00f6zelben referenciak\u00e9nt.<\/li>\n<li>\u00dcgyeljen arra, hogy t\u00fckr\u00f6zte az energiaig\u00e9ny\u00e9t; P\u00e9ld\u00e1ul, ha 16A-t haszn\u00e1l egy szekr\u00e9nyen, akkor ellen\u0151rizze, hogy a szekr\u00e9ny, amelybe k\u00f6lt\u00f6z\u00f6tt, 16A-os.<\/li>\n<li>Katalogiz\u00e1lja az egyes hardverelemeket \u00e9s a szekr\u00e9nyben tal\u00e1lhat\u00f3 pontos helyet. Az \u00e1llv\u00e1nyon l\u00e9v\u0151 szerel\u0151s\u00ednen l\u00e9v\u0151 sz\u00e1mok seg\u00edtenek azonos\u00edtani ezeket a helyeket. Kev\u00e9s dolog sokkal frusztr\u00e1l\u00f3bb, mint hogy a szekr\u00e9nyt majdnem megteljen, csak annak felismer\u00e9se \u00e9rdek\u00e9ben, hogy nincs el\u00e9g helyed, \u00e9s \u00fajra kell kezdenie.<\/li>\n<li>C\u00edmk\u00e9zze fel a szerel\u0151s\u00edneket. Noha a s\u00ednek gyakran hasonl\u00f3ak, lehet, hogy nem, \u00e9s mint tudjuk, ezeket minden egyes berendez\u00e9shez elk\u00e9sz\u00edtik. Felt\u00e9tlen\u00fcl jel\u00f6lje meg, hogy melyik berendez\u00e9s megfelel a s\u00ednnek.<\/li>\n<li>Haszn\u00e1ljon egy adatk\u00f6zponti infrastrukt\u00farakezel\u00e9si (DCIH) megold\u00e1st, hogy mozgat\u00e1s el\u0151tt t\u00e1vol\u00edtsa el az \u00f6sszes komponenst a kiszolg\u00e1l\u00f3\u00e1llv\u00e1nyokr\u00f3l, \u00e9s telep\u00edtse \u00fajra, amikor a tart\u00f3 a hely\u00e9n van. Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy az \u00d6n \u00e1ltal haszn\u00e1lt emel\u0151berendez\u00e9sek adatk\u00f6zponti haszn\u00e1latra vannak tan\u00fas\u00edtva.<\/li>\n<li>Ez a megfelel\u0151 id\u0151 a k\u00e1belek vagy t\u00e1pegys\u00e9gek \u00e1tszervez\u00e9s\u00e9hez, ha sz\u00fcks\u00e9ges. Ez azt is jelenti, hogy j\u00f3 ideje elt\u00e1vol\u00edtani azokat a fel nem haszn\u00e1lt k\u00e1beleket, amelyeket valaki h\u00e1trahagyott.<\/li>\n<li>A g\u00f6rg\u0151kkel ell\u00e1tott \u00e1llv\u00e1nyokat \u00fcresen kell mozgatni, mik\u00f6zben a lehet\u0151 legalacsonyabbra kell nyomni, hogy elker\u00fclj\u00e9k a billen\u00e9st. A szekr\u00e9ny ajtajainak \u00e9s oldalainak elt\u00e1vol\u00edt\u00e1sa kev\u00e9sb\u00e9 biztos\u00edtja a stabilit\u00e1st, de cs\u00f6kkentheti a s\u00faly\u00e1t. K\u00eds\u00e9rletezzen, hogy megtudja, melyik felel meg legjobban az \u00d6n ig\u00e9nyeinek.<\/li>\n<li>Alaposan tiszt\u00edtsa meg a burkolatot bel\u00fclr\u0151l \u00e9s k\u00edv\u00fclr\u0151l a por elt\u00e1vol\u00edt\u00e1s\u00e1hoz, \u00e9s ellen\u0151rizze m\u00e9g egyszer, hogy a s\u00ednek nem hajlottak-e meg \u00e9s megfelel\u0151en vannak-e r\u00f6gz\u00edtve. Ez a megfelel\u0151 id\u0151 a s\u00e9r\u00fclt s\u00ednek cser\u00e9j\u00e9re.<\/li>\n<li>F\u00fcggetlen\u00fcl att\u00f3l, hogy tov\u00e1bbra is k\u00e1belt vezet a padl\u00f3 alatt, vagy fejp\u00e1ly\u00e1kat haszn\u00e1l, tegye meg az extra l\u00e9p\u00e9st, \u00e9s t\u00e1vol\u00edtsa el a r\u00e9gi k\u00e1beleket.<\/li>\n<li>Ha van \u00e1tmeneti helyis\u00e9ge vagy laborat\u00f3riuma, ahol dolgozhat, el\u0151bb vigye oda a hardvert, \u00e9s hagyja, hogy a hardver technik\u00e1k mindent megtiszt\u00edtsanak, mik\u00f6zben kicser\u00e9lnek minden kopott alkatr\u00e9szt, p\u00e9ld\u00e1ul ventil\u00e1tort. Am\u00edg \u0151k ezt csin\u00e1lj\u00e1k, mozgatja a kabinet, \u00e9s m\u0171k\u00f6dteti az erej\u00e9t.<\/li>\n<\/ul>\n<p><strong>Okok, hogy a szerver\u00e1llv\u00e1nyokat ne mozd\u00edts\u00e1k el teljesen bet\u00f6ltve:<\/strong><\/p>\n<ul>\n<li>A szerver\u00e1llv\u00e1ny \u00f6sszeeshet, meghajolhat vagy leeshet, \u00e9s szem\u00e9lyi s\u00e9r\u00fcl\u00e9seket okozhat, vagy megrong\u00e1lhatja a berendez\u00e9seket.<\/li>\n<li>A s\u00ednek meghajolhatnak, haszn\u00e1lhatatlann\u00e1 t\u00e9ve \u0151ket (a hajl\u00edtott s\u00edneket neh\u00e9z, ha nem is lehetetlen jav\u00edtani)<\/li>\n<li>A legt\u00f6bb szerver \u00e1llv\u00e1nyt, kereket, csavart, r\u00f6gz\u00edt\u0151eszk\u00f6zt stb. Nem szabad mozg\u00e1s szempontj\u00e1b\u00f3l oszt\u00e1lyozni, \u00e9s b\u00e1r vannak erre tervezett szekr\u00e9nyek, k\u00e9ts\u00e9ges, hogy ezeket haszn\u00e1l-e, mivel nagyon specializ\u00e1l\u00f3dtak.<\/li>\n<li>Az emelt padl\u00f3k nem rendelkeznek pontterhel\u00e9ssel, ha sok mozg\u00f3 eszk\u00f6z, p\u00e9ld\u00e1ul k\u00e9zi teheraut\u00f3 eset\u00e9ben cs\u00f6kkentik a s\u00falyeloszl\u00e1st.<\/li>\n<li>Az emelt padl\u00f3ra \u00e9s a ketrec k\u00fcsz\u00f6b\u00e9re a legt\u00f6bb g\u00f6rg\u0151n\u00e9l nagyobb kerekek sz\u00fcks\u00e9gesek, hogy biztons\u00e1gosan megfordulhassanak rajtuk.<\/li>\n<li>\u00c9s mindenekel\u0151tt \u00e9rtsd meg, mi\u00e9rt akarja \u00e1thelyezni az eg\u00e9sz szekr\u00e9nyt, \u00e9s fontolgathatj\u00e1k \u00fajra. Lehet, hogy nem tudja lerakni a szekr\u00e9nyt, vagy \u00fagy gondolja, hogy id\u0151megtakar\u00edt\u00e1st jelenthet. A legt\u00f6bb adatk\u00f6zpont-technik\u00e1val besz\u00e9lt\u00fcnk, ez \u00e1ltal\u00e1ban csak id\u0151megtakar\u00edt\u00e1s. Ne feledje, hogy a ServerLIFT a legjobb \u00e9s k\u00f6vetkezetesen legmegb\u00edzhat\u00f3bb id\u0151takar\u00e9kos.<\/li>\n<\/ul>\n<p>Some quotes to consider (from Dell servers \u2013 Moving a Server rack):<\/p>\n<p>MrTom (Programmer)<\/p>\n<p>- Mindenk\u00e9ppen t\u00e1vol\u00edts el mindent! Egyszer ler\u00fagtam egy tart\u00f3t egy k\u00e1belfuratb\u00f3l, \u00e9s ez el\u00e9g f\u00e9lelmetes volt, \u00e9s csak n\u00e9h\u00e1ny fokkal megd\u00f6nt\u00f6tt\u00e9k (nem is pr\u00f3b\u00e1ltam mozgatni). \u00dagy hangzik, mint egy hetes munka pazarl\u00e1sa;) \u201d<\/p>\n<p>Megmenthette volna id\u0151t \u00e9s neh\u00e9z emel\u0151ket a <a title=\"SL 500 ServerLIFT\" href=\"https:\/\/serverlift.com\/hu\/data-center-lifts\/sl-500x\/\">SL-500X ServerLIFT<\/a>?<\/p>","protected":false},"excerpt":{"rendered":"<p>Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":17159,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":"","_wpscppro_dont_share_socialmedia":null,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"","_instagram_share_type":"default","_medium_share_type":"","_threads_share_type":"","_google_business_share_type":"","_selected_social_profile":[],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[78],"tags":[],"class_list":["post-13986","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/serverlift.com\/hu\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/\" \/>\n<meta property=\"og:locale\" content=\"hu_HU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae\" \/>\n<meta property=\"og:description\" content=\"Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/serverlift.com\/hu\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/\" \/>\n<meta property=\"og:site_name\" content=\"ServerLIFT\u00ae\" \/>\n<meta property=\"article:published_time\" content=\"2011-01-31T20:52:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-31T22:47:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1030\" \/>\n\t<meta property=\"og:image:height\" content=\"992\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"David Zuckerman\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"},\"author\":{\"name\":\"David Zuckerman\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\"},\"headline\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets\",\"datePublished\":\"2011-01-31T20:52:18+00:00\",\"dateModified\":\"2025-07-31T22:47:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"},\"wordCount\":1116,\"image\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"articleSection\":[\"Tech LIFT\"],\"inLanguage\":\"hu\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\",\"url\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\",\"name\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets - ServerLIFT\u00ae\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"datePublished\":\"2011-01-31T20:52:18+00:00\",\"dateModified\":\"2025-07-31T22:47:29+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#breadcrumb\"},\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\",\"url\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"contentUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"width\":1030,\"height\":992,\"caption\":\"Rack Cabinet\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/serverlift.com\\\/hu\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#website\",\"url\":\"https:\\\/\\\/serverlift.com\\\/\",\"name\":\"ServerLIFT\u00ae\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/serverlift.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"hu\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\",\"name\":\"David Zuckerman\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"url\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"contentUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"caption\":\"David Zuckerman\"},\"url\":\"https:\\\/\\\/serverlift.com\\\/hu\\\/author\\\/david-z\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/serverlift.com\/hu\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","og_locale":"hu_HU","og_type":"article","og_title":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","og_description":"Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]","og_url":"https:\/\/serverlift.com\/hu\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","og_site_name":"ServerLIFT\u00ae","article_published_time":"2011-01-31T20:52:18+00:00","article_modified_time":"2025-07-31T22:47:29+00:00","og_image":[{"width":1030,"height":992,"url":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","type":"image\/jpeg"}],"author":"David Zuckerman","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#article","isPartOf":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"},"author":{"name":"David Zuckerman","@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af"},"headline":"Conducting Server Moves with Fully Loaded Racks\/Cabinets","datePublished":"2011-01-31T20:52:18+00:00","dateModified":"2025-07-31T22:47:29+00:00","mainEntityOfPage":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"},"wordCount":1116,"image":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"thumbnailUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","articleSection":["Tech LIFT"],"inLanguage":"hu"},{"@type":"WebPage","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","url":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","name":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","isPartOf":{"@id":"https:\/\/serverlift.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"image":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"thumbnailUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","datePublished":"2011-01-31T20:52:18+00:00","dateModified":"2025-07-31T22:47:29+00:00","author":{"@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af"},"breadcrumb":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#breadcrumb"},"inLanguage":"hu","potentialAction":[{"@type":"ReadAction","target":["https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"]}]},{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage","url":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","contentUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","width":1030,"height":992,"caption":"Rack Cabinet"},{"@type":"BreadcrumbList","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/serverlift.com\/hu\/"},{"@type":"ListItem","position":2,"name":"Conducting Server Moves with Fully Loaded Racks\/Cabinets"}]},{"@type":"WebSite","@id":"https:\/\/serverlift.com\/#website","url":"https:\/\/serverlift.com\/","name":"ServerLIFT\u00ae","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/serverlift.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hu"},{"@type":"Person","@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af","name":"David Zuckerman","image":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","url":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","contentUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","caption":"David Zuckerman"},"url":"https:\/\/serverlift.com\/hu\/author\/david-z\/"}]}},"_links":{"self":[{"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/posts\/13986","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/comments?post=13986"}],"version-history":[{"count":4,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/posts\/13986\/revisions"}],"predecessor-version":[{"id":37603,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/posts\/13986\/revisions\/37603"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/media\/17159"}],"wp:attachment":[{"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/media?parent=13986"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/categories?post=13986"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/serverlift.com\/hu\/wp-json\/wp\/v2\/tags?post=13986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}