{"id":13986,"date":"2011-01-31T13:52:18","date_gmt":"2011-01-31T20:52:18","guid":{"rendered":"https:\/\/serverlift.com\/?p=13986"},"modified":"2025-07-31T22:47:29","modified_gmt":"2025-07-31T22:47:29","slug":"conducting-server-moves-fully-loaded-rackscabinets","status":"publish","type":"post","link":"https:\/\/serverlift.com\/fi\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","title":{"rendered":"Palvelinliikkeiden johtaminen t\u00e4ysin kuormattuilla telineill\u00e4 \/ kaapilla"},"content":{"rendered":"<p>\u00c4skett\u00e4in tapasin foorumin kysymyksen, jossa kysyttiin hyv\u00e4\u00e4 tapaa siirt\u00e4\u00e4 t\u00e4ysin asuttu palvelinteline tai kaappi. Lyhyesti sanottuna se vaikuttaisi hieno idea, kun otetaan huomioon suurten, yksitt\u00e4isten palvelimien siirt\u00e4misen paino ja vaikeudet. Monet IT-ihmiset sanovat minulle, ett\u00e4 teknikot suorittavat palvelinsiirron ottamalla suurimman osan komponenteista kustakin palvelimesta ennen kuin ne voivat poistaa sen telineest\u00e4, sitten siirt\u00e4v\u00e4t jokaisen osan ja kokoavat kaiken uudelleen, kun kaappi on paikallaan.<\/p>\n<p>Totuus on, ett\u00e4 ellei kaappeja ole rakennettu liikkuvuutta varten (ja usein vaikka nekin olisivatkin) siirrett\u00e4ess\u00e4 t\u00e4ysin asuttua, kaappi on harvoin hyv\u00e4 idea.<\/p>\n<p>Haarukkahissit on suunniteltu siirt\u00e4m\u00e4\u00e4n hyvin pakattuja tavaroita kuormalavalla. Olen n\u00e4hnyt tietokeskuksia, joiden kaapit ovat luiskeilla tai kuormalavoilla, ja jos t\u00e4m\u00e4 on sinun suunnitelmasi, on selv\u00e4\u00e4, ett\u00e4 sinulla on jo j\u00e4rjestelm\u00e4 koko kaapin siirt\u00e4miseen. Yleens\u00e4 n\u00e4iss\u00e4 tietokeskuksissa on eritt\u00e4in suuri k\u00e4yt\u00e4v\u00e4tila tai ne sijaitsevat Pods: ss\u00e4. J\u00e4t\u00e4 muille meille trukki lastauslaiturille. , Sill\u00e4 ei ole paikkaa siirt\u00e4\u00e4 kalliita, herkki\u00e4 IT-laitteita.<\/p>\n<p>Tarkastellaan ensin sit\u00e4, ett\u00e4 useimmissa telineiss\u00e4 ja kaapissa ei ole py\u00f6ri\u00e4 ja ett\u00e4 ne tukevat pieni\u00e4 jalkoja. Vaikka se on riitt\u00e4v\u00e4n vahva tukemaan kaapia, kun kaikki nelj\u00e4 jalkaa ovat maassa, kallistamalla kaapia asettamalla sen paino kahdelle jalalle, et vain lis\u00e4\u00e4 huomattavasti pistekuormaa, mutta my\u00f6s v\u00e4\u00e4nt\u00f6\u00e4 ohuille jaloille kulmassa, jota he eiv\u00e4t olleet. suunniteltu aiheuttamaan ne taivuttamaan tai murtumaan. Useimpia telineit\u00e4 ja kaappeja ei yksinkertaisesti ole tarkoitettu siirt\u00e4m\u00e4\u00e4n asuttaessaan.<\/p>\n<p>Jotkut uudemmat telinej\u00e4rjestelm\u00e4t on suunniteltu liikkuviksi laitteiden ollessa asennettuna, vaikka vaikeudet t\u00e4ynn\u00e4 k\u00e4yt\u00e4viss\u00e4 saattavat johtaa tilanteeseen, josta on vaikea p\u00e4\u00e4st\u00e4 eroon, vaikka siirrett\u00e4v\u00e4t kaapitkin voivat olla ongelmallisia tiukassa k\u00e4yt\u00e4v\u00e4kokoonpanossa. Suurinta osaa on vaikea siirt\u00e4\u00e4 nostetun lattian poikki ja tiukka risteyskohta voi pys\u00e4ytt\u00e4\u00e4 kaiken.<\/p>\n<p><strong>Omaisuuden siirt\u00e4minen on helpompi tapa.<\/strong><\/p>\n<p><strong>Suurin osa liikkeist\u00e4 kuuluu kolmelle alueelle:<\/strong><\/p>\n<p><strong> Siirtyminen uuteen kaappiin tai datakeskukseen<\/strong><\/p>\n<p><strong> Varojen yhdist\u00e4minen pienemm\u00e4ksi jalanj\u00e4lkeksi tai uudeksi j\u00e4rjestelyksi<\/strong><\/p>\n<p><strong> Asustetaan uusi teline \/ kaappi uutta k\u00e4ytt\u00f6\u00f6nottoa varten <\/strong><\/p>\n<ul>\n<li>Jos olet palkannut tehokkuuskonsultin, muista ilmoittaa heille uusi kokoonpano ennen kuin siirr\u00e4t mit\u00e4\u00e4n. Jos tehokkuusmalli on luotu, pieninkin muutos voi muuttaa hienoa tasapainoa tilan, j\u00e4\u00e4hdytyksen ja tehon v\u00e4lill\u00e4.<\/li>\n<\/ul>\n<ul>\n<li>Merkitse kaikki kaapelit ja tarvikkeet, jos et ole jo tehnyt niin. Nykyp\u00e4iv\u00e4n suuntaus on k\u00e4ytt\u00e4\u00e4 v\u00e4rikoodattuja kaapeleita, mutta k\u00e4ym\u00e4st\u00e4si riippumatta, kaavi asetukset aina ennen mink\u00e4\u00e4n poistamista. Jos k\u00e4ytit Visioa tai muuta ohjelmistoa konfiguroinnin suunnitteluun, muista sis\u00e4llytt\u00e4\u00e4 kaikki riippuvuudet kaapiin varmistaaksesi, ett\u00e4 et ole kriittinen j\u00e4rjestelm\u00e4n toiselle osalle. Pid\u00e4 suunnittelukaavio l\u00e4hell\u00e4 aina viittausta varten.<\/li>\n<li>Varmista, ett\u00e4 olet heijastellut virrankulutusta; Esimerkiksi, jos k\u00e4yt\u00e4t 16A kaappissa, varmista, ett\u00e4 muutettava kaappi on 16A.<\/li>\n<li>Luetteloi jokainen laitteisto ja tarkka sijainti kaapissa. Telineen kiinnityskiskojen numerot auttavat sinua tunnistamaan n\u00e4m\u00e4 paikat. Jotkut asiat ovat turhauttavampia kuin kaapin saaminen melkein t\u00e4yteen, vain ymm\u00e4rt\u00e4\u00e4ksesi, ett\u00e4 sinulla on v\u00e4h\u00e4n tilaa ja sinun on aloitettava alusta.<\/li>\n<li>Merkitse kiinnityskiskot. Vaikka kiskot n\u00e4ytt\u00e4v\u00e4t usein samanlaisilta, ne eiv\u00e4t v\u00e4ltt\u00e4m\u00e4tt\u00e4 ole, ja kuten tied\u00e4mme, ne tehd\u00e4\u00e4n jokaiselle laitteelle. Muista merkit\u00e4, mik\u00e4 laite kiskoa vastaa.<\/li>\n<li>K\u00e4yt\u00e4 Data Center Infrastructure Handling (DCIH) -ratkaisua poistaaksesi kaikki komponentit palvelimien telineist\u00e4 ennen siirtoa ja asenna ne uudelleen, kun teline on paikallaan. Varmista, ett\u00e4 kaikki k\u00e4ytt\u00e4m\u00e4si nostolaitteet on sertifioitu k\u00e4ytett\u00e4v\u00e4ksi datakeskuksissa.<\/li>\n<li>T\u00e4m\u00e4 on hyv\u00e4 aika muuttaa tarvittaessa kaapeleita tai virtal\u00e4hteit\u00e4. T\u00e4m\u00e4 tarkoittaa my\u00f6s, ett\u00e4 on hyv\u00e4 aika poistaa k\u00e4ytt\u00e4m\u00e4tt\u00f6m\u00e4t kaapelit, jotka joku j\u00e4tti.<\/li>\n<li>Py\u00f6rill\u00e4 varustetut telineet tulee siirt\u00e4\u00e4 tyhjiksi ty\u00f6nt\u00e4m\u00e4ll\u00e4 niin alas mahdolliseen telineeseen kuin mahdollista kaatumisen v\u00e4ltt\u00e4miseksi. Kaapin ovien ja sivujen poistaminen voi tehd\u00e4 siit\u00e4 v\u00e4hemm\u00e4n vakaan, mutta my\u00f6s v\u00e4hent\u00e4\u00e4 painoa. Kokeile n\u00e4hd\u00e4ksesi mik\u00e4 sopii parhaiten tarpeisiisi.<\/li>\n<li>Puhdista kaappi perusteellisesti sis\u00e4- ja ulkopuolelta p\u00f6lyn poistamiseksi ja tarkista viel\u00e4 kerran, ettei kiskoja taipu ja ole kiinnitetty kunnolla. T\u00e4m\u00e4 on hyv\u00e4 aika korvata vaurioituneet liukukiskot.<\/li>\n<li>Kaapeloitko edelleen lattian alla tai k\u00e4yt\u00e4tk\u00f6 yl\u00e4raiteita, ota ylim\u00e4\u00e4r\u00e4inen vaihe ja poista vanhat kaapelit.<\/li>\n<li>Jos sinulla on pukuhuone tai laboratorio ty\u00f6skennell\u00e4, siirr\u00e4 laitteisto ensin sinne ja anna laitteiden tekij\u00f6iden puhdistaa kaikki ja vaihtaa kuluneet komponentit, kuten tuulettimet. Kun he tekev\u00e4t niin, siirr\u00e4t kaapia ja k\u00e4yt\u00e4t voimaa.<\/li>\n<\/ul>\n<p><strong>Syyt olla siirt\u00e4m\u00e4tt\u00e4 palvelintelineit\u00e4 t\u00e4yteen ladattuina:<\/strong><\/p>\n<ul>\n<li>Palvelinteline voi romahtaa, taipua tai pudota ja loukkaa henkil\u00f6st\u00f6\u00e4 tai vaurioittaa laitteita.<\/li>\n<li>Kiskot voivat taipua, mik\u00e4 tekee niist\u00e4 hy\u00f6dyt\u00f6nt\u00e4 (taivutetut kiskot on vaikea, ellei mahdoton korjata)<\/li>\n<li>Suurinta osaa palvelinhyllyj\u00e4, py\u00f6ri\u00e4, pultteja, kiinnityslaitteita jne. Ei ole luokiteltu liikkumiselle, ja vaikka on olemassa t\u00e4h\u00e4n suunniteltuja kaappeja, on ep\u00e4varmaa, ett\u00e4 k\u00e4yt\u00e4t niit\u00e4, koska ne ovat erikoistuneita.<\/li>\n<li>Korotetulla lattialla ei ehk\u00e4 ole pistekuormitusta, kun pienenn\u00e4t painon jakautumista monista liikkuvista laitteista, kuten k\u00e4sik\u00e4ytt\u00f6isest\u00e4 kuorma-autosta.<\/li>\n<li>Korotetut lattiat ja h\u00e4kkikynnykset tarvitsevat py\u00f6ri\u00e4, jotka ovat suurempia kuin useimmat py\u00f6r\u00e4t, jotta ne turvallisesti kaataisivat yli.<\/li>\n<li>Ja ennen kaikkea ymm\u00e4rr\u00e4 syy, miksi haluat siirt\u00e4\u00e4 koko kaapin, ja voit harkita uudelleen. Onko se, ett\u00e4 et voi purkaa kaappia, vai onko mielest\u00e4si se s\u00e4\u00e4st\u00e4\u00e4 aikaa. Suurimman osan ajasta olemme puhuneet datakeskuksen tekij\u00f6ille, se on yleens\u00e4 vain ajan s\u00e4\u00e4st\u00f6\u00e4. Muista, ett\u00e4 ServerLIFT on paras ja johdonmukaisimmin luotettava s\u00e4\u00e4st\u00f6aja t\u00e4h\u00e4n.<\/li>\n<\/ul>\n<p>Some quotes to consider (from Dell servers \u2013 Moving a Server rack):<\/p>\n<p>MrTom (Programmer)<\/p>\n<p>\u201dPoista ehdottomasti kaikki! Ty\u00f6ntelin telineen kerran kaapeliaukosta alas ja se oli tarpeeksi pelottavaa ja sit\u00e4 kallistettiin vain muutama aste yli (en edes yritt\u00e4nyt siirt\u00e4\u00e4 sit\u00e4). Kuulostaa hyv\u00e4lt\u00e4 tavalta tuhlata viikon ty\u00f6t\u00e4;) \u201d<\/p>\n<p>Voisiko h\u00e4n s\u00e4\u00e4st\u00e4\u00e4 jonkin aikaa ja raskaan nostamisen k\u00e4ytt\u00e4m\u00e4ll\u00e4 <a title=\"SL 500 ServerLIFT\" href=\"https:\/\/serverlift.com\/fi\/data-center-lifts\/sl-500x\/\">SL-500X ServerLIFT<\/a>?<\/p>","protected":false},"excerpt":{"rendered":"<p>Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":17159,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":"","_wpscppro_dont_share_socialmedia":null,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"","_instagram_share_type":"default","_medium_share_type":"","_threads_share_type":"","_google_business_share_type":"","_selected_social_profile":[],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[78],"tags":[],"class_list":["post-13986","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/serverlift.com\/fi\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/\" \/>\n<meta property=\"og:locale\" content=\"fi_FI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae\" \/>\n<meta property=\"og:description\" content=\"Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/serverlift.com\/fi\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/\" \/>\n<meta property=\"og:site_name\" content=\"ServerLIFT\u00ae\" \/>\n<meta property=\"article:published_time\" content=\"2011-01-31T20:52:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-31T22:47:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1030\" \/>\n\t<meta property=\"og:image:height\" content=\"992\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"David Zuckerman\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"},\"author\":{\"name\":\"David Zuckerman\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\"},\"headline\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets\",\"datePublished\":\"2011-01-31T20:52:18+00:00\",\"dateModified\":\"2025-07-31T22:47:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"},\"wordCount\":1116,\"image\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"articleSection\":[\"Tech LIFT\"],\"inLanguage\":\"fi\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\",\"url\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\",\"name\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets - ServerLIFT\u00ae\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"datePublished\":\"2011-01-31T20:52:18+00:00\",\"dateModified\":\"2025-07-31T22:47:29+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#breadcrumb\"},\"inLanguage\":\"fi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#primaryimage\",\"url\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"contentUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2011\\\/01\\\/rack-cabinet-554476_1920-1030x992.jpg\",\"width\":1030,\"height\":992,\"caption\":\"Rack Cabinet\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/blog\\\/conducting-server-moves-fully-loaded-rackscabinets\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/serverlift.com\\\/fi\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Conducting Server Moves with Fully Loaded Racks\\\/Cabinets\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#website\",\"url\":\"https:\\\/\\\/serverlift.com\\\/\",\"name\":\"ServerLIFT\u00ae\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/serverlift.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fi\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/#\\\/schema\\\/person\\\/89c8e60203b5b6470914cefd109847af\",\"name\":\"David Zuckerman\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"url\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"contentUrl\":\"https:\\\/\\\/serverlift.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/David-small-96x96.jpg\",\"caption\":\"David Zuckerman\"},\"url\":\"https:\\\/\\\/serverlift.com\\\/fi\\\/author\\\/david-z\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/serverlift.com\/fi\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","og_locale":"fi_FI","og_type":"article","og_title":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","og_description":"Recently, I came across a forum question asking for a good way to move a fully populated server rack or cabinet. In short it would seem a great idea, given the weight and difficulty of moving large, individual servers. Many IT people tell me their technicians carry out a server move by taking out most [&hellip;]","og_url":"https:\/\/serverlift.com\/fi\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","og_site_name":"ServerLIFT\u00ae","article_published_time":"2011-01-31T20:52:18+00:00","article_modified_time":"2025-07-31T22:47:29+00:00","og_image":[{"width":1030,"height":992,"url":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","type":"image\/jpeg"}],"author":"David Zuckerman","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#article","isPartOf":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"},"author":{"name":"David Zuckerman","@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af"},"headline":"Conducting Server Moves with Fully Loaded Racks\/Cabinets","datePublished":"2011-01-31T20:52:18+00:00","dateModified":"2025-07-31T22:47:29+00:00","mainEntityOfPage":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"},"wordCount":1116,"image":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"thumbnailUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","articleSection":["Tech LIFT"],"inLanguage":"fi"},{"@type":"WebPage","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","url":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/","name":"Conducting Server Moves with Fully Loaded Racks\/Cabinets - ServerLIFT\u00ae","isPartOf":{"@id":"https:\/\/serverlift.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"image":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage"},"thumbnailUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","datePublished":"2011-01-31T20:52:18+00:00","dateModified":"2025-07-31T22:47:29+00:00","author":{"@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af"},"breadcrumb":{"@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#breadcrumb"},"inLanguage":"fi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/"]}]},{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#primaryimage","url":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","contentUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2011\/01\/rack-cabinet-554476_1920-1030x992.jpg","width":1030,"height":992,"caption":"Rack Cabinet"},{"@type":"BreadcrumbList","@id":"https:\/\/serverlift.com\/blog\/conducting-server-moves-fully-loaded-rackscabinets\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/serverlift.com\/fi\/"},{"@type":"ListItem","position":2,"name":"Conducting Server Moves with Fully Loaded Racks\/Cabinets"}]},{"@type":"WebSite","@id":"https:\/\/serverlift.com\/#website","url":"https:\/\/serverlift.com\/","name":"ServerLIFT\u00ae","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/serverlift.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fi"},{"@type":"Person","@id":"https:\/\/serverlift.com\/#\/schema\/person\/89c8e60203b5b6470914cefd109847af","name":"David Zuckerman","image":{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","url":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","contentUrl":"https:\/\/serverlift.com\/wp-content\/uploads\/2019\/03\/David-small-96x96.jpg","caption":"David Zuckerman"},"url":"https:\/\/serverlift.com\/fi\/author\/david-z\/"}]}},"_links":{"self":[{"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/posts\/13986","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/comments?post=13986"}],"version-history":[{"count":4,"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/posts\/13986\/revisions"}],"predecessor-version":[{"id":37603,"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/posts\/13986\/revisions\/37603"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/media\/17159"}],"wp:attachment":[{"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/media?parent=13986"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/categories?post=13986"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/serverlift.com\/fi\/wp-json\/wp\/v2\/tags?post=13986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}